Usage : Test leds and led lights
1.FMS-6000 SPETRUM ANALYSIS SYSTEM
1.rapid scanning technology, greatly improve the measurement speed, full spectrum scanning fastest time 10 s. Using spectral integral technology, achieve higher luminous flux measurement precision and linearity.
2.monochromator spectrometer. Photomultiplier tube and other core components for the international famous brand high testing precision, high sensitivity, low stray light.
2) the higher luminosity measurement spectra method was adopted to realize flux test precision. Photometric detector V (lambda) match of national level, the software embedded detector V (lambda) matching data.
S basic measurement functions:
1) to test relative spectral power distribution, chromaticity coordinates, dominant wavelength, peak wavelength, spectral purity, color temperature, color rendering index, half width, luminous flux (integral), radiation power, the red, the color tolerance, the parameters such as temperature, satisfies the requirement of CIE international commission on illumination light and color measurement.
2) EPS software can automatically describe all kinds of light source light flux after starting/power/voltage/current curve of change over time.
3. the main technical indicators:
Items | Statistic | Notice |
Wavelength measurement range | 380nm-780nm |
|
Wavelength accuracy | More or less 0.2nm |
|
Wavelength repeatability | More or less 0.1nm |
|
Chromaticity coordinates(x,y) accuracy | More or less 0.0003 | Under standard light source A |
Spectrum sampling interval | 5nm.1nm ,0.1nm |
|
Photometric system accurcy | Class one |
|
Corelated color temperature measurement range | 1500k -25000k |
|
Corelated color temperature measurement accuracy | More or less 0.3% | Under standard light source A |
Luminous flux measurement range | 0.01lm~200000lm | With suitable integrating sphere |
Color tolerance accuracy | More or less 0.5 |
|
Main wavelength range | 380nm-780nm |
|
Main wavelength accuracy | More or less 0.2nm |
|
Color rendering range | 0-100 | More or less(0.3%+0.3) |
Temperature measurement range | -10℃~80℃ | ±0.5℃ |
2. 1.2 optical fiber
Use for optical signal transmission integrating sphere between spectral analysis system and integrating sphere ,the high performance, light failure is small.
3.Φ0.30m LED special integrating sphere and 1.5 m sphere
Integrating sphere spraying process is good, high spectral reflectance, diffuse good performance, good stability for a long time, easy to clean, not yellow;
Design in accordance with international standards, the ball can be loaded within two feet four feet/upright type LED lamp holder, it can realize the LED inside the ball 4 PI test. Integrating sphere side open Φ 60 mm hole and jig interface,use LED 2 PI outside of the ball test method ,the adapter supplier of various LED fixture (SMDLED, HPLED, etc.). Supplier provide free test is suitable for the 2 PI method Φ 30 high power LED (one) common fixture one only.
4.FC-2 Light path converter
when use big and small integrating sphere test share a spectrum analyzer, use the FC - 2 light path converter can avoid the fiber optic insertion and repeated calibration work, greatly raises ˎ ̥ high test efficiency and test personnel's workload. This design is convenient to use and accurate positioning.
5.LSS05 General standard light source(spectral power distribution/flux)
OSRAM lamp beads as original halogen lamp, 12 v / 5 w for spectral analysis system of color temperature (spectrum) calibration and photometer flux calibration (dissemination). High stability, high reproducibility, quantity can be traced back to the China metrology institute (NIM).
6. integrating spheres
together with the spectral analysis system or photometer ues for light luminosity chromaticity parameters testing systems.
Integrating sphere spraying process is good, high spectral reflectance, diffuse good performance, good stability for a long time, easy to clean, not yellow;
the ball inside the lamp holder: E40, match [E40 transfer E27, E14 transfer E27, E27 turn GU10 (vertical)], G13 / G5 (level);
electrical interfaces: lamp holder bracket of samples and testing all fabric have power supply and voltage test side, the four wire method, can eliminate grew up with two wire system circuit current (especially the LED light source such as low voltage power line voltage loss caused by voltage test is inaccurate;
way to open the door: unilateral rotating wheel/rail support type manually open and close;
7.wp3005 precise digital display DC current and voltage stabilized supply
1) voltage stability: ≤ 5×10-5 ,reading + 2 mv
2) voltage range: 5 v / 10v / 25 v / 50 v;
3) current stability: ≤ 1×10-4, readings +0.5mA ;
4) range of ammeter range: 0.5A/1A/2.5A/5A
5) voltage resolution :0.0001 V, (0.0000 V ~ 3.000 V); 0.001 V, (3.000 V ~ 50.000 V);
6) voltage accuracy: + / - (0.02% reading+ 0.01%reading range + 2 words);
7) current resolution: 0.0001 A, (0.0000 A to 0.0000 A);
8)current accuracy: + / - (0.02%reading + 0.01%reading range + 2 words);
9) maximum output power: 150 VA
10)The maximum output voltage : 30 V
11) the largest output current: 5 A
8. UI2012 AC-DC electric parameter measurement instrument
our window at the same time display voltage, current, power, power factor, with RS - 232 communication function;
main technical indicators:
1) can measure ac, dc, ac/dc signal;
2) current and power with maximum,minmum limit alarm, especially suitable for the production line extensive testing,
3) voltage range: AC: 5 ~ 600 v, DC: 1 ~ 600 v, current range: AC & DC: 0.005 ~ 20.00 A, range automatic conversion;
4) accuracy: + / - (0.4%reading +0.1% reading range + 1 word)
9.PDF-500 Precision frequency test power supply
FDP series precision frequency test power supply is a kind of high power, low distortion, high stability of the power frequency pure sine wave power supply, integration of the source table. Adopt AC - DC - AC frequency conversion and digital waveform synthesis and waveform feedback, the integral period sampling of high-speed high precision, zero output impedance, isolated floating output, voltage current abnormal, and overheating protection, boot current limit and a series of advanced technology to ensure the accuracy of the power, pure nature, reliability and security. Use advanced 32-bit MCU control and measurement, RS - 232 communication can realize intelligent programmable output operations.
the main technical indicators:
1. The input voltage, AC 220 v/AC 110 v (internal change jumper wire), plus or minus 10% 1 phi 2 w 50/60 hz
2. The output voltage: 0 ~ 150 v or 0 ~ 300 v two notches
3. The output voltage temperature coefficient: plus or minus 0.2% / ℃
4. The total harmonic distortion: ≦ 0.2% (at 50/60 hz) (ats Resister Load, PF = 1, THD -r measurement)
5. The output line: 1 phi 2 w
6. The output capacity: 500 VA
7. The largest output current: test must meet the following conditions: AC power supply voltage plus or minus 5%, THD ≦ 2%, plus or minus 5% frequency;
@ 120 v / 4.2 A;@ 240 v / 2.1 A;
Power stability factor: + / - 0.2% (ACV + / - 10%; THD ≦ 2%; frequency + / - 5%) (@ 80% Fullscal output voltage, LOAD = 0 ~ 50%; PF = 1)
9. The output frequency: 45 hz ~ 65 hz
10. The frequency resolution(realization): 0.01 Hz;
11. The frequency accuracy: + / - 0.05%
12. photoelectric color measurement system cabinet (with door and panel)
international standard open file size, the high quality cold rolling steel plate, the grey tones, well made. The FMS - 6000 / X - 5, WP3005, UI2012, FDP500 in this standard cabinets, make a complete set of photoelectric instrument as a whole the beauty is generous. Save a space, convenient reading operation, good resistance to electromagnetic interference. Cabinet install ac/dc switch, convenient wiring, easy to control operations. With excellent dustproof glass door, in line with international trends.